CTX915883
MetaFrame 1.8
MetaFrame 1.8
1970-01-01
1970-01-01

Apply workaround.

Issue

When using Appcfg.exe from the Published Application Manager to join a MetaFrame 1.8 Service Pack 3 server to an existing farm, the following error message may be received:

"The following published applications in the server farm are in the process of being loaded to validate their groups and user accounts. Please try joining the server farm later."

The error message is followed by a list of published applications from the farm the server is trying to join.

Reproduction Steps

1. Build the following computers:

A. AWindows NT 4.0 Service Pack 6 primary domain controller (PDC)

B. A Windows 2000 Service Pack 2/MetaFrame 1.8 Service Pack 3 member server in the Windows NT 4.0 domain

C. AWindows 2000 Service Pack 2 Active Directory computer in mixed mode

D. AWindows 2000 Service Pack 2/MetaFrame 1.8 Service Pack 3 member server in the Active Directory domain

2. Establish two-way trusts between the Windows NT 4.0 and Windows 2000 Active Directory domains.

3. Put the Windows NT 4.0 domain member server in Farm A and the Windows 2000 Active Directory Server in Farm B.

4. Publish Notepad on the server in Farm A and Calculator on the server in Farm B.

Add domain users from both domains to both applications. Close Published Application Manager.

5. Open Published Application Manager from either domain.

Attempt to change the farm memership to the other farm. Farm A migrating to Farm B produces the error message above with the Calculator. Farm B migrating to Farm A produces the error message above with Notepad.

NOTE: If the following error message appears,

"Server "Name of server" cannot become the default server because you have neither read nor write access privilege to it."

you are most likely running the Published Application Manager as a user who is not a member of the local administrators group. By default, trusted domain accounts are not made members of a server local administrators group. See Error: Server "servername" cannot become the default server because you have neither read nor write access privilege to it..

Workaround

Delete all applications from both farms or, at minimum, the farm trying to be joined. The servers will join to the same farm. Republish all the applications.